Master Heat R290 – Air-to-Water Heat Pumps
Master Heat R290 Heat Pump, Single-Phase 4.1–16 kW
Full-inverter monobloc air-to-water heat pump with natural refrigerant R290, for heating, cooling and hot water. Single-phase 220-240 V, 50/60 Hz, heating output 4.1–16 kW (A7/W35).
014.1 – 16 kWHeating capacity
02A+++Energy class
0363 – 132 kgNet weight
Heat Pump Related Products

Key features

- 01Full-inverter monobloc air-to-water heat pump
- 02Natural refrigerant R290
- 03Seasonal space heating energy class A+++ at 35 °C and A++ at 55 °C
- 04Flow temperature up to 75 °C, domestic hot water up to 70 °C
- 05Operates down to -25 °C outdoor temperature
- 06Heating and cooling
- 07Single-phase power supply 220-240 V, 50/60 Hz
Applications
- Space heating with radiators or underfloor heating
- Cooling with fan coils or underfloor cooling
- Domestic hot water with a heat pump DHW tank
- Residential and light commercial buildings
What is included
- Outdoor heat pump unit
Goes well with
- Master Heat R290 indoor unit
- HydroTower One / HydroBox One
- FC 1 / FC 2 tanks for heat pump
- Buffer tanks
- Complete sets: Heat Pump Package A / B
Technical data
| General | ||||||
|---|---|---|---|---|---|---|
| Installation | Outdoor | Outdoor | Outdoor | Outdoor | Outdoor | |
| Dimensions W × D × H | 920 × 415 × 560 | 1115 × 415 × 900 | 1115 × 415 × 900 | 1115 × 415 × 900 | 1115 × 415 × 1332 | mm |
| Net weight | 63 | 90 | 98 | 110 | 132 | kg |
| Max. temperature | 75 | 75 | 75 | 75 | 75 | °C |
| Connections | Water inlet / outlet G1″ M | Water inlet / outlet G1″ M | Water inlet / outlet G1″ M | Water inlet / outlet G1″ M | Water inlet / outlet G1″ M | |
| Gross weight | 70 | 104 | 112 | 125 | 148 | kg |
| Packing dimensions | 960 × 500 × 710 | 1155 × 500 × 1035 | 1155 × 500 × 1035 | 1155 × 500 × 1035 | 1155 × 500 × 1460 | mm |
| Energy | ||||||
| Energy class | A+++ | A+++ | A+++ | A+++ | A+++ | |
| COP A7/W35 | 4.6 | 4.81 | 4.5 | 4.48 | 4.69 | |
| SCOP 35 °C | 4.73 | 4.75 | 4.72 | 4.83 | 4.82 | |
| SCOP 55 °C | 3.54 | 3.63 | 3.65 | 3.6 | 3.62 | |
| Heat pump | ||||||
| Heating capacity | 4.1 | 6.4 | 9.15 | 12.2 | 16 | kW |
| Cooling capacity | 3.6 | 6.25 | 8.85 | 10.8 | 14.85 | kW |
| Refrigerant | R290 | R290 | R290 | R290 | R290 | |
| Refrigerant charge | 0.45 | 0.8 | 0.85 | 1.2 | 1.4 | kg |
| Sound power outdoor unit (dB(A)) | 48 | 51 | 54 | 54 | 56 | |
| Max. flow temperature | 75 | 75 | 75 | 75 | 75 | °C |
| Operating range, outdoor air | Heating and DHW −25 to 45 · cooling 10 to 45 | Heating and DHW −25 to 45 · cooling 10 to 45 | Heating and DHW −25 to 45 · cooling 10 to 45 | Heating and DHW −25 to 45 · cooling 10 to 45 | Heating and DHW −25 to 45 · cooling 10 to 45 | °C |
| Electrical | ||||||
| Power supply | 1-phase | 1-phase | 1-phase | 1-phase | 1-phase | |
| IP class | IPX4 (outdoor unit) | IPX4 (outdoor unit) | IPX4 (outdoor unit) | IPX4 (outdoor unit) | IPX4 (outdoor unit) | |
Available Models
| Model | ERP code | |
|---|---|---|
| 4.1 kW | 2001000385 | |
| 6.4 kW | 2001000341 | |
| 9.15 kW | 2001000330 | |
| 12.2 kW | 2001000331 | |
| 16 kW | 2001000344 |